FREQUENTLY ASKED QUESTIONS

Q. WHAT IS POLYURETHANE FOAM?
A. Polyurethane Foam is a two part liquid that when spray-applied, expands up to 30% to form a monolithic, seamless, lightweight roof surface normally used in low slope roofing systems.

Q. IS IT NECESSARY TO COAT SPRAY-APPLIED (SPF) FOAM ROOFING?
A. Yes, Polyurethane foam must be coated to protect the foam from the destructive U.V. rays from the sun. Polyurethane roof foam must always be coated with white high- reflective acrylic, silicone or urethane coatings for foam protection and energy savings benefits.

Q. IS YOUR ROOF COATING ENERGY STAR APPROVED?
A. Yes, Our "Kool Kote" coatings have been tested and meet the ASTM Reflectance Standards for Initial Solar Reflectance and (3) year reflectance requirements. SWD 1929R and SWD 1929F acrylic white Quik-Shield ®coatings are shown on The Energy Star and California Qualified Product Lists.

Q. IS YOUR ROOF COATING APPROVED BY THE COOL ROOF RATING COUNCIL?
A. Yes, SWD 1929F Quik-Shield ® coating has been tested and approved to ASTM standards and is listed by the CRRC (Cool Roof Rating Council) for Solar Reflectance of 83% and Thermal Emittance of 92%.

Q. IS A SPRAY-APPLIED FOAM ROOF SYSTEM EXPENSIVE?
A. The price of a SPF system, although higher than common built-up roofs can actually be 30 % less when considering the 'Life-cycle costs of the roof over a period of time. Heating and cooling costs can drop dramatically with SWD reflective coatings that may reduce energy bills up to 50%.

Q. HOW LONG DOES POLYURETHANE FOAM LAST?
A. Polyurethane foam has been shown to last 25 years without internal degradation. SWD Urethane Co. and it's affiliated contracting companies, Arizona Foam & Spray has been successfully installing foam roof systems since 1969.

Q. DOES POLYURETHANE FOAM INSULATE MY ROOF?
A. Yes, It has an R-value of 6.8 per inch of foam and may be spray-applied at greater thickness') for additional insulation values.

Q. CAN I WALK ON MY SPF ROOF?
A. Yes, SPF has a normal compressive strength of 40-50 psi. and can be walked on within 24 hours. Tell your tradesmen however, they must check with us prior to doing any work on your roof in order to maintain your warranty.

Q. WHAT ABOUT FIRE RATINGS?
A. SWD SPF SYSTEMS HAVE UL 790, UL 1256, FM and ICC (International Code Council) classifications. SPF will burn and has a flame spread characteristic similar to white pine.

Q. WHAT KIND OF WARRANTY DO I HAVE ON MY SPF ROOF SYSTEM?
A. SWD Urethane Co. and it's affiliated contracting companies, offer a 'Single Source' warranty. This is extremely important to you, as it guarantees that We take responsibility for the performance of the materials and the quality of the application (including labor and materials).

Q. DOES POLYURETHANE FOAM ABSORB WATER?
A. NO, SPF is a closed cell product that does not absorb water. It does however, have a low vapor transmission rate which allows the roof to breathe and keep moisture from forming under the foam surface.

Q. WHAT IS TITLE 24
A. Title 24 is now required on most new buildings in california efective Oct 5th of 2005. It requires that most new roofs be insulated immediately on top or underneath the roof to meet new insulation, Solar Reflectance and Thermal Emiittance requirements.
SEE TITLE 24

Q. WHAT OTHER USES WOULD I HAVE FOR FOAM PRODUCTS?
A. Please check out our other sites for further ideas and information.